In the modern world where electricity is used more intensively in every field, the control of electrical panels is independent of human intervention. So much so that the re -establishment of disabled insurance and/or leakage current protection switches due to temporary cases is manually provided by human intervention, while security, time, labor loss can cause loss of labor. Sigma Elektrik, illegal current protection switches and automatic insurance added to the re -closing unit, manual operations to minimum levels while highlighting security and user ease.
What are the illegal current protection switches and automatic insurances with re -closing unit?
Automatic fuses and leakage current protection switches used in electrical panels may be disabled due to non -continuity temporary reasons. Re -commissioning these products can be provided automatically with the re -closing unit to be added to him instead of the removal of the manual installation arm.
Return Unit Illegal Current Protection Swear;
Due to any leakage current in the system, if the illegal current protection switch opens, the switch is automatically re -installed with the help of the closing unit.
In this way, due to the temporary illegal current in the system, the long-term disability of the illegal current protection switch is prevented from being disabled at the same time.
Automatic insurance with re -closing unit;
Automatic insurance, if it is disabled due to any overcurrent, the re -closure unit attached to the insurance re -established and commits the insurance. With the LED signal lamps connected to the auxiliary contact of the re -closing unit, if automatic insurance has thrown 4 times, the closure unit does not activate the automatic insurance, the signal lamp comes into play and gives visual warning.
How to use the re -closure unit in both insurance and leakage current protection switches?
For automatic fuses, the re -closure unit is easily attached to the left side of the automatic insurance as modular. Classroom inputs above the re -closing unit are given phase and neutral feeding. The auxiliary contact inputs on the klemen are connected to the button that will provide remote-opening in illegal current protection switches and to the LED signal lamp that gives alert to not being commissioned for the 4th time after being disabled 3 times in automatic insurance.
Why Sigma Re -Closing Unit should be used?
Automatic insurance and illegal current protection switches that are disabled may cause major problems from time to time. For example, illegal current protection switch or insurance may be disabled due to a temporary problem, and the intervention of the fault team causes loss of time and loss of production. In homes and cottages, the transmission of illegal current or automatic insurance with a temporary reason causes disabled in electrical devices such as refrigerator. Automatic insurance or illegal current protection switch, which is disabled in base stations, causes interruption of communication.
In addition to re -commissioning thanks to the re -closing unit auxiliary contacts, there are LED warnings in automatic fuses remote opening, illegal current protection switches.
Manual mode can be disabled by taking.
In case of maintenance or fault in the electrical panel, the re -closure unit can be taken into locking mode and energy transmission can be safely cut.